Our team has completed more than 20,000 cubic meters of facilities locally and overseas. We can provide a full suite of decontamination services regardless of the challenges.
Bio Facilities and Equipment Decontamination
· Hospitals –Isolation wards / Acute Care Facilities
· Pharmaceutical – Biologics
· Biosafety Level 2/ 3 laboratories
· Animal Facilities
· Bio Safety Cabinet
· HEPA Filter Housing
Chemical Facilities and Equipment Decon
· Pharmaceutical – Beta Lactam
· Pharmaceutical – API
Methodology
Our team has the expertise and experience with the following internationally recognised methods for decontamination.
Validation
All decontamination are validated by a 3rd party vendor.
For Chemical decontamination, chlorine dioxide gas at various concentrations and exposure times is used in an effort to achieve the pharmaceutical manufacturer’s required 3-log reduction of eight different beta-lactams on various surfaces.
For Bio decontamination, a biological indicator requiring 6-log reduction will be deployed as validation process.
Tested and Proven Technology
Safety
Successful decontamination requires the use of high concentration of chemicals beyond STEL and PEL limits. As such, safety is a top consideration during decontamination. Our team will work with our clients to provide Risk Assessments, proper PPE / APD and establish clear work procedures and approvals before commencing work.